About BIOSAFETY CABINATE CLASS II A2
Biosafety Cabinet Class II A2 is suitable to use for microbiology research in absence of volatile, toxic chemicals and radionuclide. It is widely used in biotechnology tissue cultures, hospitals, research laboratories, microbiology laboratories, pathology, colleges and universities.Superior Filtration and SafetyEquipped with a double exhaust HEPA filtration system, the Class II A2 Biosafety Cabinet removes 99.99% of particles as small as 0.3 microns. Built-in UV lamps with safety interlocks further ensure sterility, making it ideal for microbiological and pharmaceutical settings.
User-Friendly and Customizable DesignWith a motorized or manual front sash, digital airflow display, and an inclined control panel for ergonomic operation, this biosafety cabinet fits a wide range of working environments. Optional accessories including gas taps, data loggers, and power sockets are available to tailor the system to your lab's requirements.
Energy Efficient and Low NoiseThe cabinet features an energy-saving motor system and LED/fluorescent illumination delivering over 1000 lux, ensuring well-lit, comfortable workspaces. Engineered to maintain low noise (<65 dB(A)) and minimal vibration, it is perfect for sensitive laboratory procedures requiring stable conditions.
FAQ's of BIOSAFETY CABINATE CLASS II A2:
Q: How does the Class II A2 Biosafety Cabinet protect both the user and the samples?
A: This biosafety cabinet uses a double HEPA filtration system that captures 99.99% of particles down to 0.3 microns, ensuring clean air for samples while protecting users from hazardous agents. The inward airflow prevents contaminants from escaping, providing comprehensive protection.
Q: What is the typical working procedure for operating this biosafety cabinet?
A: To use the cabinet, first ensure the power supply is connected and the digital control panel is active. Slide open the front sash to the recommended height, enabling airflow. Start internal lighting and, if necessary, the UV lamp for sterilization (with the sash closed). Conduct procedures on the easy-clean stainless steel surface. After use, clean the area and run the UV lamp as per safety protocols.
Q: When should the UV lamp be activated in the biosafety cabinet?
A: The UV lamp is intended for sterilization between operations. Activate it only when no personnel are present, as safety interlocks prevent UV exposure while the sash is open. Typical cycles last 15-30 minutes, depending on your lab's protocols.
Q: Where can this Class II A2 Biosafety Cabinet be installed?
A: Its compact, rectangular bench-mounted form and sturdy caster wheels make it suitable for installation in laboratories, research centers, pharmaceutical production units, and universities across India. It requires access to a standard 220-240V AC power supply.
Q: What maintenance processes are recommended for optimal operation?
A: Routine maintenance includes daily surface cleaning, periodic replacement or washing of the pre-filter, scheduled servicing of the HEPA filters, and regular checks of the airflow and filter status via the digital display. All procedures should be done as per the user manual to maintain safety and efficiency.
Q: How does the cabinet benefit laboratory applications?
A: By offering a low-vibration and low-noise work zone with high-efficiency HEPA filters and customizable features, the cabinet maintains a controlled environment vital for sensitive procedures in microbiology, pharmaceutical research, and diagnostics, thereby improving accuracy, efficiency, and safety.